WORLD CLASS IN POLYESTER FILM 

backTECHNICAL BULLETIN
STATIC PREVENTION AND REMOVAL RECOMMENDATION

A. STATIC PREVENTION

B. REMOVAL EQUIPMENT

C. STATIC BAR PLACEMENT

The most effective placement of a static bar, no matter what design, is within one roll diameter of the point that the film loses contact with a roll. For true neutralization, the bar must be placed on the same side of the film as the roll that the film is in contact with. (See attached sketch) The reason for this is the static charge is actually only on the side of the film that is in contact with the roll.

D. STATIC MEASURMENT

Static is normally measured with a field meter. The meter we use is a Model 255 STAT-ARC METER, manufactured by Monroe Electronics.

E. TEST DEVICES

The logo HOSTAPHAN is a registered trademark of Hoechst AG and is licensed to Mitsubishi Polyester Film, Inc.

The information contained herein is, to the best of our knowledge, true and accurate, but all recommendations or suggestions are made without guarantee, since the conditions of use are beyond our control. There is no implied warranty of merchantability or fitness for purpose of the product or products described herein. In submitting this information, no liability is assumed or license or other rights express or implied given with respect to any existing or pending patent, patent applications or trademarks. The observance of all legal regulations and patents is the responsibility of the user.